{"title":"Gas \u0026 Combustion Valves","description":null,"products":[{"product_id":"8040h007-120-60-110-50-valve","title":"8040H007 120\/60, 110\/50 AC 1\/4\" Safety Shutoff Valve","description":"\u003ch3 data-section-id=\"tdf23g\" data-start=\"102\" data-end=\"200\"\u003eASCO 8040H007 Gas Combustion Solenoid Valve – 120V\/60Hz, 110V\/50Hz – Normally Closed – 1\/4\" NPT\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-end=\"236\" data-start=\"145\" data-section-id=\"12h4b5q\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8040_8215R8.pdf?v=1773352686\" target=\"_blank\"\u003e\u003cspan\u003eProduct Spec Sheet (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp data-start=\"202\" data-end=\"519\"\u003eThe \u003cstrong data-start=\"206\" data-end=\"253\"\u003eASCO 8040H007 Gas Combustion Solenoid Valve\u003c\/strong\u003e is a reliable \u003cstrong data-start=\"268\" data-end=\"345\"\u003esafety shut-off valve designed for fuel gas control in combustion systems\u003c\/strong\u003e. This normally closed, electrically operated valve automatically stops gas flow when power is removed, helping protect burners, appliances, and industrial heating equipment.\u003c\/p\u003e\n\u003cp data-start=\"521\" data-end=\"886\"\u003eEngineered for dependable performance, the 8040H007 is commonly used in \u003cstrong data-start=\"593\" data-end=\"652\"\u003eboilers, furnaces, ovens, and other gas-fired equipment\u003c\/strong\u003e where precise and safe gas flow control is essential. When energized, the valve opens to allow gas flow to the burner system. When de-energized, the valve closes immediately to shut off the gas supply, ensuring safe system operation.\u003c\/p\u003e\n\u003cp data-start=\"888\" data-end=\"1181\"\u003eThe valve operates on \u003cstrong data-start=\"910\" data-end=\"950\"\u003e120V AC at 60 Hz or 110V AC at 50 Hz\u003c\/strong\u003e, making it compatible with a wide range of commercial and industrial combustion systems. Its \u003cstrong data-start=\"1044\" data-end=\"1075\"\u003ecompact 1\/4\" NPT connection\u003c\/strong\u003e and durable aluminum body allow for easy installation in both new equipment and replacement applications.\u003c\/p\u003e\n\u003cp data-start=\"1183\" data-end=\"1371\"\u003eBuilt to meet demanding combustion safety requirements, the \u003cstrong data-start=\"1243\" data-end=\"1371\"\u003eASCO 8040 Series valves are widely used across HVAC, industrial heating, food processing, and commercial cooking industries.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1378\" data-end=\"1393\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1394\" data-end=\"1820\"\u003e\n\u003cli data-section-id=\"eky0l8\" data-start=\"1394\" data-end=\"1450\"\u003e\n\u003cp data-start=\"1396\" data-end=\"1450\"\u003eNormally closed \u003cstrong data-start=\"1412\" data-end=\"1450\"\u003egas safety shut-off solenoid valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1casgc2\" data-start=\"1451\" data-end=\"1502\"\u003e\n\u003cp data-start=\"1453\" data-end=\"1502\"\u003e\u003cstrong data-start=\"1453\" data-end=\"1483\"\u003e120V \/ 60Hz or 110V \/ 50Hz\u003c\/strong\u003e coil compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ur8w7k\" data-start=\"1503\" data-end=\"1533\"\u003e\n\u003cp data-start=\"1505\" data-end=\"1533\"\u003e\u003cstrong data-start=\"1505\" data-end=\"1533\"\u003e1\/4\" NPT pipe connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kk67er\" data-start=\"1534\" data-end=\"1577\"\u003e\n\u003cp data-start=\"1536\" data-end=\"1577\"\u003eDesigned for \u003cstrong data-start=\"1549\" data-end=\"1577\"\u003efuel gas and air service\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"256ksj\" data-start=\"1578\" data-end=\"1623\"\u003e\n\u003cp data-start=\"1580\" data-end=\"1623\"\u003eFast response for combustion safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kmw0hr\" data-start=\"1624\" data-end=\"1687\"\u003e\n\u003cp data-start=\"1626\" data-end=\"1687\"\u003eCompact aluminum body for durability and corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lt2qan\" data-start=\"1688\" data-end=\"1753\"\u003e\n\u003cp data-start=\"1690\" data-end=\"1753\"\u003eSuitable for \u003cstrong data-start=\"1703\" data-end=\"1753\"\u003ecommercial, industrial, and OEM burner systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4eako4\" data-start=\"1754\" data-end=\"1820\"\u003e\n\u003cp data-start=\"1756\" data-end=\"1820\"\u003eTrusted ASCO reliability used in combustion control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1827\" data-end=\"1854\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1855\" data-end=\"2281\"\u003e\n\u003cli data-section-id=\"14m303y\" data-start=\"1855\" data-end=\"1878\"\u003e\n\u003cp data-start=\"1857\" data-end=\"1878\"\u003e\u003cstrong data-start=\"1857\" data-end=\"1867\"\u003eModel:\u003c\/strong\u003e 8040H007\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lpn87r\" data-start=\"1879\" data-end=\"1935\"\u003e\n\u003cp data-start=\"1881\" data-end=\"1935\"\u003e\u003cstrong data-start=\"1881\" data-end=\"1896\"\u003eValve Type:\u003c\/strong\u003e 2-Way Normally Closed Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wgnrof\" data-start=\"1936\" data-end=\"1986\"\u003e\n\u003cp data-start=\"1938\" data-end=\"1986\"\u003e\u003cstrong data-start=\"1938\" data-end=\"1950\"\u003eVoltage:\u003c\/strong\u003e 120V AC (60 Hz) \/ 110V AC (50 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"clu3nd\" data-start=\"1987\" data-end=\"2014\"\u003e\n\u003cp data-start=\"1989\" data-end=\"2014\"\u003e\u003cstrong data-start=\"1989\" data-end=\"2003\"\u003ePipe Size:\u003c\/strong\u003e 1\/4\" NPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1occmb\" data-start=\"2015\" data-end=\"2046\"\u003e\n\u003cp data-start=\"2017\" data-end=\"2046\"\u003e\u003cstrong data-start=\"2017\" data-end=\"2035\"\u003eBody Material:\u003c\/strong\u003e Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q8mpwl\" data-start=\"2047\" data-end=\"2089\"\u003e\n\u003cp data-start=\"2049\" data-end=\"2089\"\u003e\u003cstrong data-start=\"2049\" data-end=\"2075\"\u003eFlow Coefficient (Cv):\u003c\/strong\u003e Approx. 1.1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7mxiyb\" data-start=\"2090\" data-end=\"2146\"\u003e\n\u003cp data-start=\"2092\" data-end=\"2146\"\u003e\u003cstrong data-start=\"2092\" data-end=\"2113\"\u003eMaximum Pressure:\u003c\/strong\u003e Up to 15 PSI (Air\/Gas Service)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2o1vwc\" data-start=\"2147\" data-end=\"2197\"\u003e\n\u003cp data-start=\"2149\" data-end=\"2197\"\u003e\u003cstrong data-start=\"2149\" data-end=\"2159\"\u003eMedia:\u003c\/strong\u003e Natural Gas, LP Gas, Air, Inert Gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xpm0iy\" data-start=\"2198\" data-end=\"2233\"\u003e\n\u003cp data-start=\"2200\" data-end=\"2233\"\u003e\u003cstrong data-start=\"2200\" data-end=\"2213\"\u003eMounting:\u003c\/strong\u003e Inline gas piping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bfh3fa\" data-start=\"2234\" data-end=\"2281\"\u003e\n\u003cp data-start=\"2236\" data-end=\"2281\"\u003e\u003cstrong data-start=\"2236\" data-end=\"2247\"\u003eSeries:\u003c\/strong\u003e ASCO 8040 Combustion Safety Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"vx2wyp\" data-start=\"2288\" data-end=\"2310\"\u003eCommon Applications\u003c\/h2\u003e\n\u003cp data-start=\"2311\" data-end=\"2425\"\u003eThe ASCO 8040H007 valve is designed for \u003cstrong data-start=\"2351\" data-end=\"2413\"\u003egas flow control and safety shut-off in combustion systems\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ibt7am\" data-start=\"2427\" data-end=\"2455\"\u003eHVAC \u0026amp; Heating Equipment\u003c\/h3\u003e\n\u003cul data-start=\"2456\" data-end=\"2685\"\u003e\n\u003cli data-section-id=\"mfz6bq\" data-start=\"2456\" data-end=\"2472\"\u003e\n\u003cp data-start=\"2458\" data-end=\"2472\"\u003eGas furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"weau2w\" data-start=\"2473\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2475\" data-end=\"2495\"\u003eCommercial heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d5evle\" data-start=\"2496\" data-end=\"2512\"\u003e\n\u003cp data-start=\"2498\" data-end=\"2512\"\u003eUnit heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qfg2xq\" data-start=\"2513\" data-end=\"2535\"\u003e\n\u003cp data-start=\"2515\" data-end=\"2535\"\u003eRooftop HVAC units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cba75p\" data-start=\"2536\" data-end=\"2562\"\u003e\n\u003cp data-start=\"2538\" data-end=\"2562\"\u003eGas-fired air handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9cfc5x\" data-start=\"2563\" data-end=\"2583\"\u003e\n\u003cp data-start=\"2565\" data-end=\"2583\"\u003eInfrared heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xz8sev\" data-start=\"2584\" data-end=\"2608\"\u003e\n\u003cp data-start=\"2586\" data-end=\"2608\"\u003eRadiant tube heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6fzbl6\" data-start=\"2609\" data-end=\"2637\"\u003e\n\u003cp data-start=\"2611\" data-end=\"2637\"\u003eHydronic heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tbg3kq\" data-start=\"2638\" data-end=\"2660\"\u003e\n\u003cp data-start=\"2640\" data-end=\"2660\"\u003eCondensing boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ec5opk\" data-start=\"2661\" data-end=\"2685\"\u003e\n\u003cp data-start=\"2663\" data-end=\"2685\"\u003eNon-condensing boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"k8smhh\" data-start=\"2687\" data-end=\"2714\"\u003eBoiler \u0026amp; Burner Systems\u003c\/h3\u003e\n\u003cul data-start=\"2715\" data-end=\"2902\"\u003e\n\u003cli data-section-id=\"irbh4z\" data-start=\"2715\" data-end=\"2737\"\u003e\n\u003cp data-start=\"2717\" data-end=\"2737\"\u003eIndustrial boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"llv47s\" data-start=\"2738\" data-end=\"2760\"\u003e\n\u003cp data-start=\"2740\" data-end=\"2760\"\u003eCommercial boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mtp06p\" data-start=\"2761\" data-end=\"2790\"\u003e\n\u003cp data-start=\"2763\" data-end=\"2790\"\u003eBurner management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vw0f5u\" data-start=\"2791\" data-end=\"2818\"\u003e\n\u003cp data-start=\"2793\" data-end=\"2818\"\u003ePilot burner assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jd8g0p\" data-start=\"2819\" data-end=\"2845\"\u003e\n\u003cp data-start=\"2821\" data-end=\"2845\"\u003eMain burner gas trains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tk0ep5\" data-start=\"2846\" data-end=\"2873\"\u003e\n\u003cp data-start=\"2848\" data-end=\"2873\"\u003eFlame safeguard systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11ytbk0\" data-start=\"2874\" data-end=\"2902\"\u003e\n\u003cp data-start=\"2876\" data-end=\"2902\"\u003eCombustion control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1rdqcer\" data-start=\"2904\" data-end=\"2936\"\u003eIndustrial Heating Equipment\u003c\/h3\u003e\n\u003cul data-start=\"2937\" data-end=\"3106\"\u003e\n\u003cli data-section-id=\"1oyaaum\" data-start=\"2937\" data-end=\"2957\"\u003e\n\u003cp data-start=\"2939\" data-end=\"2957\"\u003eIndustrial ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"owk0x7\" data-start=\"2958\" data-end=\"2982\"\u003e\n\u003cp data-start=\"2960\" data-end=\"2982\"\u003ePowder coating ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gzubm7\" data-start=\"2983\" data-end=\"3005\"\u003e\n\u003cp data-start=\"2985\" data-end=\"3005\"\u003ePaint curing ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"199mak5\" data-start=\"3006\" data-end=\"3021\"\u003e\n\u003cp data-start=\"3008\" data-end=\"3021\"\u003eBatch ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"odox8c\" data-start=\"3022\" data-end=\"3040\"\u003e\n\u003cp data-start=\"3024\" data-end=\"3040\"\u003eConveyor ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gg58un\" data-start=\"3041\" data-end=\"3068\"\u003e\n\u003cp data-start=\"3043\" data-end=\"3068\"\u003eHeat treatment furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iih8wr\" data-start=\"3069\" data-end=\"3078\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3078\"\u003eKilns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ywnsq\" data-start=\"3079\" data-end=\"3106\"\u003e\n\u003cp data-start=\"3081\" data-end=\"3106\"\u003eDryers and curing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"15v3n0c\" data-start=\"3108\" data-end=\"3152\"\u003eFood Service \u0026amp; Food Processing Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3153\" data-end=\"3301\"\u003e\n\u003cli data-section-id=\"znz54l\" data-start=\"3153\" data-end=\"3173\"\u003e\n\u003cp data-start=\"3155\" data-end=\"3173\"\u003eCommercial ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wujd0v\" data-start=\"3174\" data-end=\"3190\"\u003e\n\u003cp data-start=\"3176\" data-end=\"3190\"\u003eBakery ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ozoh0g\" data-start=\"3191\" data-end=\"3205\"\u003e\n\u003cp data-start=\"3193\" data-end=\"3205\"\u003eDeck ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o6mlz8\" data-start=\"3206\" data-end=\"3230\"\u003e\n\u003cp data-start=\"3208\" data-end=\"3230\"\u003eConveyor pizza ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ckkrhu\" data-start=\"3231\" data-end=\"3251\"\u003e\n\u003cp data-start=\"3233\" data-end=\"3251\"\u003eRotisserie ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15nk6nc\" data-start=\"3252\" data-end=\"3264\"\u003e\n\u003cp data-start=\"3254\" data-end=\"3264\"\u003eProofers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"62vt29\" data-start=\"3265\" data-end=\"3280\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3280\"\u003eFood dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18fnppm\" data-start=\"3281\" data-end=\"3301\"\u003e\n\u003cp data-start=\"3283\" data-end=\"3301\"\u003eCommercial smokers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"k24tdt\" data-start=\"3303\" data-end=\"3343\"\u003eManufacturing \u0026amp; Processing Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3344\" data-end=\"3498\"\u003e\n\u003cli data-section-id=\"29b52f\" data-start=\"3344\" data-end=\"3364\"\u003e\n\u003cp data-start=\"3346\" data-end=\"3364\"\u003eGas-fired dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hrpwv3\" data-start=\"3365\" data-end=\"3384\"\u003e\n\u003cp data-start=\"3367\" data-end=\"3384\"\u003eProcess heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d02udq\" data-start=\"3385\" data-end=\"3406\"\u003e\n\u003cp data-start=\"3387\" data-end=\"3406\"\u003eThermal oxidizers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1thidtz\" data-start=\"3407\" data-end=\"3423\"\u003e\n\u003cp data-start=\"3409\" data-end=\"3423\"\u003eIncinerators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13sv1ts\" data-start=\"3424\" data-end=\"3446\"\u003e\n\u003cp data-start=\"3426\" data-end=\"3446\"\u003eIndustrial burners\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ajg1x3\" data-start=\"3447\" data-end=\"3469\"\u003e\n\u003cp data-start=\"3449\" data-end=\"3469\"\u003eGas mixing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o656wu\" data-start=\"3470\" data-end=\"3498\"\u003e\n\u003cp data-start=\"3472\" data-end=\"3498\"\u003eGas distribution manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1u7qc7r\" data-start=\"3500\" data-end=\"3537\"\u003eAgriculture \u0026amp; Specialty Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3538\" data-end=\"3635\"\u003e\n\u003cli data-section-id=\"3al68\" data-start=\"3538\" data-end=\"3554\"\u003e\n\u003cp data-start=\"3540\" data-end=\"3554\"\u003eGrain dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oz7gmj\" data-start=\"3555\" data-end=\"3577\"\u003e\n\u003cp data-start=\"3557\" data-end=\"3577\"\u003eGreenhouse heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4ue47z\" data-start=\"3578\" data-end=\"3601\"\u003e\n\u003cp data-start=\"3580\" data-end=\"3601\"\u003eCrop drying systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1238n90\" data-start=\"3602\" data-end=\"3635\"\u003e\n\u003cp data-start=\"3604\" data-end=\"3635\"\u003eAgricultural combustion heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1v2qwi5\" data-start=\"3642\" data-end=\"3675\"\u003eTypical Installation Locations\u003c\/h2\u003e\n\u003cp data-start=\"3676\" data-end=\"3712\"\u003eThis valve is commonly installed in:\u003c\/p\u003e\n\u003cul data-start=\"3714\" data-end=\"3869\"\u003e\n\u003cli data-section-id=\"1luek8e\" data-start=\"3714\" data-end=\"3730\"\u003e\n\u003cp data-start=\"3716\" data-end=\"3730\"\u003e\u003cstrong data-start=\"3716\" data-end=\"3730\"\u003eGas trains\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mvcfgu\" data-start=\"3731\" data-end=\"3752\"\u003e\n\u003cp data-start=\"3733\" data-end=\"3752\"\u003e\u003cstrong data-start=\"3733\" data-end=\"3752\"\u003ePilot gas lines\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hrf6mc\" data-start=\"3753\" data-end=\"3787\"\u003e\n\u003cp data-start=\"3755\" data-end=\"3787\"\u003e\u003cstrong data-start=\"3755\" data-end=\"3787\"\u003eMain burner gas supply lines\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"marsxb\" data-start=\"3788\" data-end=\"3822\"\u003e\n\u003cp data-start=\"3790\" data-end=\"3822\"\u003e\u003cstrong data-start=\"3790\" data-end=\"3822\"\u003eCombustion control manifolds\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1563mc6\" data-start=\"3823\" data-end=\"3869\"\u003e\n\u003cp data-start=\"3825\" data-end=\"3869\"\u003e\u003cstrong data-start=\"3825\" data-end=\"3869\"\u003eSafety shut-off stages in burner systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"6hv2og\" data-start=\"3876\" data-end=\"3895\"\u003ePackage Includes\u003c\/h2\u003e\n\u003cul data-start=\"3896\" data-end=\"3976\"\u003e\n\u003cli data-section-id=\"nvc9fh\" data-start=\"3896\" data-end=\"3943\"\u003e\n\u003cp data-start=\"3898\" data-end=\"3943\"\u003e(1) ASCO 8040H007 Combustion Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1e3ymgv\" data-start=\"3944\" data-end=\"3976\"\u003e\n\u003cp data-start=\"3946\" data-end=\"3976\"\u003eFactory-installed 120V AC coil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42642964217952,"sku":"8040H007","price":133.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/series_8040.jpg?v=1773352657"},{"product_id":"8040h007-24-60-valve","title":"8040H007 24\/60 AC 1\/4\" Safety Shutoff Valve","description":"\u003ch2 data-section-id=\"zki8mz\" data-start=\"0\" data-end=\"86\"\u003eASCO 8040H007 Gas Combustion Solenoid Valve – 24V\/60Hz – Normally Closed – 1\/4\" NPT\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h2\u003e\n\u003ch4 data-section-id=\"12h4b5q\" data-start=\"145\" data-end=\"236\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8040_8215R8.pdf?v=1773352686\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan\u003eProduct Spec Sheet (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp data-start=\"88\" data-end=\"458\"\u003eThe \u003cstrong data-start=\"92\" data-end=\"148\"\u003eASCO 8040H007 24V\/60Hz Gas Combustion Solenoid Valve\u003c\/strong\u003e is a normally closed safety shut-off valve designed to control the flow of \u003cstrong data-start=\"224\" data-end=\"291\"\u003enatural gas, LP gas, air, and inert gases in combustion systems\u003c\/strong\u003e. This electrically operated valve opens when energized and automatically closes when power is removed, providing fast and reliable protection for gas-fired equipment.\u003c\/p\u003e\n\u003cp data-start=\"460\" data-end=\"809\"\u003eCommonly used in \u003cstrong data-start=\"477\" data-end=\"521\"\u003eburner management systems and gas trains\u003c\/strong\u003e, the ASCO 8040H007 helps ensure safe operation of boilers, furnaces, ovens, and other heating equipment. Its compact design, durable aluminum body, and dependable solenoid operation make it ideal for both OEM installations and replacement in commercial and industrial combustion systems.\u003c\/p\u003e\n\u003cp data-start=\"811\" data-end=\"1085\"\u003eOperating on \u003cstrong data-start=\"824\" data-end=\"848\"\u003e24 volts AC at 60 Hz\u003c\/strong\u003e, this valve is compatible with many low-voltage control circuits used in HVAC equipment and automated burner systems. The \u003cstrong data-start=\"971\" data-end=\"1003\"\u003e1\/4\" NPT threaded connection\u003c\/strong\u003e allows easy installation in pilot lines, burner manifolds, and gas supply piping.\u003c\/p\u003e\n\u003cp data-start=\"1087\" data-end=\"1315\"\u003eDesigned for reliability in demanding environments, the \u003cstrong data-start=\"1143\" data-end=\"1315\"\u003eASCO 8040 series valves are widely used across HVAC, manufacturing, food service, and industrial heating applications where dependable gas shut-off control is critical.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1322\" data-end=\"1337\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1338\" data-end=\"1745\"\u003e\n\u003cli data-section-id=\"eky0l8\" data-start=\"1338\" data-end=\"1394\"\u003e\n\u003cp data-start=\"1340\" data-end=\"1394\"\u003eNormally closed \u003cstrong data-start=\"1356\" data-end=\"1394\"\u003egas safety shut-off solenoid valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iy6xdb\" data-start=\"1395\" data-end=\"1437\"\u003e\n\u003cp data-start=\"1397\" data-end=\"1437\"\u003e\u003cstrong data-start=\"1397\" data-end=\"1437\"\u003e24V AC \/ 60 Hz low-voltage operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ex5zsc\" data-start=\"1438\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1440\" data-end=\"1478\"\u003e\u003cstrong data-start=\"1440\" data-end=\"1478\"\u003e1\/4\" NPT threaded pipe connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kdiwgn\" data-start=\"1479\" data-end=\"1539\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1539\"\u003eDesigned for \u003cstrong data-start=\"1494\" data-end=\"1539\"\u003enatural gas, LP gas, air, and inert gases\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"256ksj\" data-start=\"1540\" data-end=\"1585\"\u003e\n\u003cp data-start=\"1542\" data-end=\"1585\"\u003eFast response for combustion safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zbt2bs\" data-start=\"1586\" data-end=\"1622\"\u003e\n\u003cp data-start=\"1588\" data-end=\"1622\"\u003eCompact aluminum body construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lt2qan\" data-start=\"1623\" data-end=\"1688\"\u003e\n\u003cp data-start=\"1625\" data-end=\"1688\"\u003eSuitable for \u003cstrong data-start=\"1638\" data-end=\"1688\"\u003ecommercial, industrial, and OEM burner systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ij1ba1\" data-start=\"1689\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1691\" data-end=\"1745\"\u003eReliable performance in demanding heating applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1752\" data-end=\"1779\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1780\" data-end=\"2234\"\u003e\n\u003cli data-section-id=\"14m303y\" data-start=\"1780\" data-end=\"1803\"\u003e\n\u003cp data-start=\"1782\" data-end=\"1803\"\u003e\u003cstrong data-start=\"1782\" data-end=\"1792\"\u003eModel:\u003c\/strong\u003e 8040H007\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"140i0a\" data-start=\"1804\" data-end=\"1846\"\u003e\n\u003cp data-start=\"1806\" data-end=\"1846\"\u003e\u003cstrong data-start=\"1806\" data-end=\"1817\"\u003eSeries:\u003c\/strong\u003e ASCO 8040 Combustion Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lpn87r\" data-start=\"1847\" data-end=\"1903\"\u003e\n\u003cp data-start=\"1849\" data-end=\"1903\"\u003e\u003cstrong data-start=\"1849\" data-end=\"1864\"\u003eValve Type:\u003c\/strong\u003e 2-Way Normally Closed Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1niq6xu\" data-start=\"1904\" data-end=\"1927\"\u003e\n\u003cp data-start=\"1906\" data-end=\"1927\"\u003e\u003cstrong data-start=\"1906\" data-end=\"1918\"\u003eVoltage:\u003c\/strong\u003e 24V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16gl30i\" data-start=\"1928\" data-end=\"1952\"\u003e\n\u003cp data-start=\"1930\" data-end=\"1952\"\u003e\u003cstrong data-start=\"1930\" data-end=\"1944\"\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"clu3nd\" data-start=\"1953\" data-end=\"1980\"\u003e\n\u003cp data-start=\"1955\" data-end=\"1980\"\u003e\u003cstrong data-start=\"1955\" data-end=\"1969\"\u003ePipe Size:\u003c\/strong\u003e 1\/4\" NPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1occmb\" data-start=\"1981\" data-end=\"2012\"\u003e\n\u003cp data-start=\"1983\" data-end=\"2012\"\u003e\u003cstrong data-start=\"1983\" data-end=\"2001\"\u003eBody Material:\u003c\/strong\u003e Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q8mpwl\" data-start=\"2013\" data-end=\"2055\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2055\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2041\"\u003eFlow Coefficient (Cv):\u003c\/strong\u003e Approx. 1.1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7mxiyb\" data-start=\"2056\" data-end=\"2112\"\u003e\n\u003cp data-start=\"2058\" data-end=\"2112\"\u003e\u003cstrong data-start=\"2058\" data-end=\"2079\"\u003eMaximum Pressure:\u003c\/strong\u003e Up to 15 PSI (Air\/Gas Service)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2o1vwc\" data-start=\"2113\" data-end=\"2163\"\u003e\n\u003cp data-start=\"2115\" data-end=\"2163\"\u003e\u003cstrong data-start=\"2115\" data-end=\"2125\"\u003eMedia:\u003c\/strong\u003e Natural Gas, LP Gas, Air, Inert Gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"aktgbp\" data-start=\"2164\" data-end=\"2205\"\u003e\n\u003cp data-start=\"2166\" data-end=\"2205\"\u003e\u003cstrong data-start=\"2166\" data-end=\"2180\"\u003eOperation:\u003c\/strong\u003e Direct acting solenoid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"enyno1\" data-start=\"2206\" data-end=\"2234\"\u003e\n\u003cp data-start=\"2208\" data-end=\"2234\"\u003e\u003cstrong data-start=\"2208\" data-end=\"2219\"\u003eWeight:\u003c\/strong\u003e Approx. 1.8 lb\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"vx2wyp\" data-start=\"2241\" data-end=\"2263\"\u003eCommon Applications\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1byr61e\" data-start=\"2265\" data-end=\"2291\"\u003eHVAC \u0026amp; Heating Systems\u003c\/h3\u003e\n\u003cul data-start=\"2292\" data-end=\"2478\"\u003e\n\u003cli data-section-id=\"mfz6bq\" data-start=\"2292\" data-end=\"2308\"\u003e\n\u003cp data-start=\"2294\" data-end=\"2308\"\u003eGas furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d5evle\" data-start=\"2309\" data-end=\"2325\"\u003e\n\u003cp data-start=\"2311\" data-end=\"2325\"\u003eUnit heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qfg2xq\" data-start=\"2326\" data-end=\"2348\"\u003e\n\u003cp data-start=\"2328\" data-end=\"2348\"\u003eRooftop HVAC units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fwzzsp\" data-start=\"2349\" data-end=\"2365\"\u003e\n\u003cp data-start=\"2351\" data-end=\"2365\"\u003eAir handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1a7yekx\" data-start=\"2366\" data-end=\"2385\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2385\"\u003eRadiant heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9cfc5x\" data-start=\"2386\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2388\" data-end=\"2406\"\u003eInfrared heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6fzbl6\" data-start=\"2407\" data-end=\"2435\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2435\"\u003eHydronic heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tbg3kq\" data-start=\"2436\" data-end=\"2458\"\u003e\n\u003cp data-start=\"2438\" data-end=\"2458\"\u003eCondensing boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9ko000\" data-start=\"2459\" data-end=\"2478\"\u003e\n\u003cp data-start=\"2461\" data-end=\"2478\"\u003eGas-fired boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"15jb73n\" data-start=\"2480\" data-end=\"2511\"\u003eBurner \u0026amp; Combustion Systems\u003c\/h3\u003e\n\u003cul data-start=\"2512\" data-end=\"2674\"\u003e\n\u003cli data-section-id=\"1mtp06p\" data-start=\"2512\" data-end=\"2541\"\u003e\n\u003cp data-start=\"2514\" data-end=\"2541\"\u003eBurner management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"29l2x\" data-start=\"2542\" data-end=\"2567\"\u003e\n\u003cp data-start=\"2544\" data-end=\"2567\"\u003eGas burner assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14db57r\" data-start=\"2568\" data-end=\"2590\"\u003e\n\u003cp data-start=\"2570\" data-end=\"2590\"\u003ePilot burner lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jd8g0p\" data-start=\"2591\" data-end=\"2617\"\u003e\n\u003cp data-start=\"2593\" data-end=\"2617\"\u003eMain burner gas trains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tk0ep5\" data-start=\"2618\" data-end=\"2645\"\u003e\n\u003cp data-start=\"2620\" data-end=\"2645\"\u003eFlame safeguard systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11ytbk0\" data-start=\"2646\" data-end=\"2674\"\u003e\n\u003cp data-start=\"2648\" data-end=\"2674\"\u003eCombustion control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1rdqcer\" data-start=\"2676\" data-end=\"2708\"\u003eIndustrial Heating Equipment\u003c\/h3\u003e\n\u003cul data-start=\"2709\" data-end=\"2870\"\u003e\n\u003cli data-section-id=\"1oyaaum\" data-start=\"2709\" data-end=\"2729\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2729\"\u003eIndustrial ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"odox8c\" data-start=\"2730\" data-end=\"2748\"\u003e\n\u003cp data-start=\"2732\" data-end=\"2748\"\u003eConveyor ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"owk0x7\" data-start=\"2749\" data-end=\"2773\"\u003e\n\u003cp data-start=\"2751\" data-end=\"2773\"\u003ePowder coating ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gzubm7\" data-start=\"2774\" data-end=\"2796\"\u003e\n\u003cp data-start=\"2776\" data-end=\"2796\"\u003ePaint curing ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"199mak5\" data-start=\"2797\" data-end=\"2812\"\u003e\n\u003cp data-start=\"2799\" data-end=\"2812\"\u003eBatch ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gg58un\" data-start=\"2813\" data-end=\"2840\"\u003e\n\u003cp data-start=\"2815\" data-end=\"2840\"\u003eHeat treatment furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iih8wr\" data-start=\"2841\" data-end=\"2850\"\u003e\n\u003cp data-start=\"2843\" data-end=\"2850\"\u003eKilns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ybhkp0\" data-start=\"2851\" data-end=\"2870\"\u003e\n\u003cp data-start=\"2853\" data-end=\"2870\"\u003eIndustrial dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"i71fjy\" data-start=\"2872\" data-end=\"2911\"\u003eFood Service \u0026amp; Processing Equipment\u003c\/h3\u003e\n\u003cul data-start=\"2912\" data-end=\"3039\"\u003e\n\u003cli data-section-id=\"znz54l\" data-start=\"2912\" data-end=\"2932\"\u003e\n\u003cp data-start=\"2914\" data-end=\"2932\"\u003eCommercial ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wujd0v\" data-start=\"2933\" data-end=\"2949\"\u003e\n\u003cp data-start=\"2935\" data-end=\"2949\"\u003eBakery ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p721jl\" data-start=\"2950\" data-end=\"2965\"\u003e\n\u003cp data-start=\"2952\" data-end=\"2965\"\u003ePizza ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ckkrhu\" data-start=\"2966\" data-end=\"2986\"\u003e\n\u003cp data-start=\"2968\" data-end=\"2986\"\u003eRotisserie ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k07lyb\" data-start=\"2987\" data-end=\"3015\"\u003e\n\u003cp data-start=\"2989\" data-end=\"3015\"\u003eConveyor cooking systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z6755b\" data-start=\"3016\" data-end=\"3039\"\u003e\n\u003cp data-start=\"3018\" data-end=\"3039\"\u003eFood drying equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ef69a9\" data-start=\"3041\" data-end=\"3078\"\u003eManufacturing \u0026amp; Process Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3079\" data-end=\"3208\"\u003e\n\u003cli data-section-id=\"d02udq\" data-start=\"3079\" data-end=\"3100\"\u003e\n\u003cp data-start=\"3081\" data-end=\"3100\"\u003eThermal oxidizers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qodtg8\" data-start=\"3101\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3103\" data-end=\"3131\"\u003eIndustrial process heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"29b52f\" data-start=\"3132\" data-end=\"3152\"\u003e\n\u003cp data-start=\"3134\" data-end=\"3152\"\u003eGas-fired dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"164tqrh\" data-start=\"3153\" data-end=\"3179\"\u003e\n\u003cp data-start=\"3155\" data-end=\"3179\"\u003eCombustion air systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o656wu\" data-start=\"3180\" data-end=\"3208\"\u003e\n\u003cp data-start=\"3182\" data-end=\"3208\"\u003eGas distribution manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"15u481h\" data-start=\"3210\" data-end=\"3236\"\u003eAgricultural Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3237\" data-end=\"3298\"\u003e\n\u003cli data-section-id=\"3al68\" data-start=\"3237\" data-end=\"3253\"\u003e\n\u003cp data-start=\"3239\" data-end=\"3253\"\u003eGrain dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oz7gmj\" data-start=\"3254\" data-end=\"3276\"\u003e\n\u003cp data-start=\"3256\" data-end=\"3276\"\u003eGreenhouse heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gkr2vz\" data-start=\"3277\" data-end=\"3298\"\u003e\n\u003cp data-start=\"3279\" data-end=\"3298\"\u003eCrop drying systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1v2qwi5\" data-start=\"3305\" data-end=\"3338\"\u003eTypical Installation Locations\u003c\/h2\u003e\n\u003cp data-start=\"3339\" data-end=\"3375\"\u003eThe valve is typically installed in:\u003c\/p\u003e\n\u003cul data-start=\"3377\" data-end=\"3532\"\u003e\n\u003cli data-section-id=\"1luek8e\" data-start=\"3377\" data-end=\"3393\"\u003e\n\u003cp data-start=\"3379\" data-end=\"3393\"\u003e\u003cstrong data-start=\"3379\" data-end=\"3393\"\u003eGas trains\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nst0fx\" data-start=\"3394\" data-end=\"3422\"\u003e\n\u003cp data-start=\"3396\" data-end=\"3422\"\u003e\u003cstrong data-start=\"3396\" data-end=\"3422\"\u003ePilot gas supply lines\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pwsjtc\" data-start=\"3423\" data-end=\"3458\"\u003e\n\u003cp data-start=\"3425\" data-end=\"3458\"\u003e\u003cstrong data-start=\"3425\" data-end=\"3458\"\u003eMain burner gas supply piping\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tjw5rc\" data-start=\"3459\" data-end=\"3485\"\u003e\n\u003cp data-start=\"3461\" data-end=\"3485\"\u003e\u003cstrong data-start=\"3461\" data-end=\"3485\"\u003eCombustion manifolds\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1563mc6\" data-start=\"3486\" data-end=\"3532\"\u003e\n\u003cp data-start=\"3488\" data-end=\"3532\"\u003e\u003cstrong data-start=\"3488\" data-end=\"3532\"\u003eSafety shut-off stages in burner systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"6hv2og\" data-start=\"3539\" data-end=\"3558\"\u003ePackage Includes\u003c\/h2\u003e\n\u003cul data-start=\"3559\" data-end=\"3646\"\u003e\n\u003cli data-section-id=\"18s1kmg\" data-start=\"3559\" data-end=\"3610\"\u003e\n\u003cp data-start=\"3561\" data-end=\"3610\"\u003e(1) ASCO 8040H007 Gas Combustion Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17a9txm\" data-start=\"3611\" data-end=\"3646\"\u003e\n\u003cp data-start=\"3613\" data-end=\"3646\"\u003eFactory-installed \u003cstrong data-start=\"3631\" data-end=\"3646\"\u003e24V AC coil\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42642964742240,"sku":"8040H007","price":133.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/series_8040.jpg?v=1773352657"},{"product_id":"8040h008-120-60-110-50-valve","title":"8040H008 120\/60, 110\/50 AC 3\/8\" Safety shutoff Valve","description":"\u003ch3 data-section-id=\"12h4b5q\" data-start=\"145\" data-end=\"236\"\u003eASCO 8040H008 Gas Combustion Solenoid Valve – 120\/60, 110\/50 – 3\/8\" NPT – Normally Closed\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8040_8215R8.pdf?v=1773352686\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan\u003eProduct Spec Sheet (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"238\" data-end=\"559\"\u003eThe \u003cstrong data-start=\"242\" data-end=\"289\"\u003eASCO 8040H008 Gas Combustion Solenoid Valve\u003c\/strong\u003e is a normally closed, direct-acting safety shutoff valve designed for controlling \u003cstrong data-start=\"372\" data-end=\"411\"\u003efuel gas flow in combustion systems\u003c\/strong\u003e. This valve automatically stops gas flow when electrical power is removed, helping protect burners and heating equipment from unsafe gas discharge.\u003c\/p\u003e\n\u003cp data-start=\"561\" data-end=\"912\"\u003ePart of the trusted \u003cstrong data-start=\"581\" data-end=\"601\"\u003eASCO 8040 series\u003c\/strong\u003e, this valve is widely used in \u003cstrong data-start=\"632\" data-end=\"680\"\u003ecommercial and industrial gas burner systems\u003c\/strong\u003e, where dependable gas shutoff and precise control are required. When energized, the valve opens to allow gas flow to the burner; when de-energized, it closes immediately to stop the gas supply. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"914\" data-end=\"1255\"\u003eThe \u003cstrong data-start=\"918\" data-end=\"979\"\u003e8040H008 operates on 120V AC at 60 Hz or 110V AC at 50 Hz\u003c\/strong\u003e, making it suitable for many HVAC and industrial combustion control systems. Its \u003cstrong data-start=\"1061\" data-end=\"1079\"\u003e3\/8\" NPT ports\u003c\/strong\u003e provide greater flow capacity than smaller valves in the same series, making it ideal for main burner lines and larger pilot gas systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1257\" data-end=\"1507\"\u003eConstructed with a \u003cstrong data-start=\"1276\" data-end=\"1315\"\u003edurable aluminum body and NBR seals\u003c\/strong\u003e, the valve is built for long service life in demanding heating environments and is approved for use as a \u003cstrong data-start=\"1421\" data-end=\"1468\"\u003egas safety shutoff valve by UL, FM, and CSA\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1514\" data-end=\"1528\"\u003eKey Features\u003c\/h1\u003e\n\u003cul data-start=\"1529\" data-end=\"1990\"\u003e\n\u003cli data-section-id=\"m6nqmg\" data-start=\"1529\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1531\" data-end=\"1575\"\u003e\u003cstrong data-start=\"1531\" data-end=\"1575\"\u003eNormally closed gas safety shutoff valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rl374w\" data-start=\"1576\" data-end=\"1624\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1624\"\u003e\u003cstrong data-start=\"1578\" data-end=\"1624\"\u003e120V AC \/ 60Hz or 110V AC \/ 50Hz operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7b2x66\" data-start=\"1625\" data-end=\"1660\"\u003e\n\u003cp data-start=\"1627\" data-end=\"1660\"\u003e\u003cstrong data-start=\"1627\" data-end=\"1660\"\u003e3\/8\" NPT threaded connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fftixb\" data-start=\"1661\" data-end=\"1691\"\u003e\n\u003cp data-start=\"1663\" data-end=\"1691\"\u003eDirect-acting solenoid valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yzwkzc\" data-start=\"1692\" data-end=\"1747\"\u003e\n\u003cp data-start=\"1694\" data-end=\"1747\"\u003eAluminum body for durability and corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12zz1nn\" data-start=\"1748\" data-end=\"1806\"\u003e\n\u003cp data-start=\"1750\" data-end=\"1806\"\u003eSuitable for \u003cstrong data-start=\"1763\" data-end=\"1806\"\u003enatural gas, LP gas, air, and inert gas\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"256ksj\" data-start=\"1807\" data-end=\"1852\"\u003e\n\u003cp data-start=\"1809\" data-end=\"1852\"\u003eFast response for combustion safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12rqkbl\" data-start=\"1853\" data-end=\"1898\"\u003e\n\u003cp data-start=\"1855\" data-end=\"1898\"\u003eUL \/ FM \/ CSA approved safety shutoff valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ae1qbs\" data-start=\"1899\" data-end=\"1990\"\u003e\n\u003cp data-start=\"1901\" data-end=\"1990\"\u003eMountable in any position for flexible installation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"1997\" data-end=\"2023\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cul data-start=\"2024\" data-end=\"2619\"\u003e\n\u003cli data-section-id=\"14m2nk1\" data-start=\"2024\" data-end=\"2047\"\u003e\n\u003cp data-start=\"2026\" data-end=\"2047\"\u003e\u003cstrong data-start=\"2026\" data-end=\"2036\"\u003eModel:\u003c\/strong\u003e 8040H008\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"70wnbv\" data-start=\"2048\" data-end=\"2073\"\u003e\n\u003cp data-start=\"2050\" data-end=\"2073\"\u003e\u003cstrong data-start=\"2050\" data-end=\"2061\"\u003eSeries:\u003c\/strong\u003e ASCO 8040\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7nphc3\" data-start=\"2074\" data-end=\"2114\"\u003e\n\u003cp data-start=\"2076\" data-end=\"2114\"\u003e\u003cstrong data-start=\"2076\" data-end=\"2091\"\u003eValve Type:\u003c\/strong\u003e 2-Way Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14tbemr\" data-start=\"2115\" data-end=\"2149\"\u003e\n\u003cp data-start=\"2117\" data-end=\"2149\"\u003e\u003cstrong data-start=\"2117\" data-end=\"2131\"\u003eOperation:\u003c\/strong\u003e Normally Closed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v8u6b1\" data-start=\"2150\" data-end=\"2201\"\u003e\n\u003cp data-start=\"2152\" data-end=\"2201\"\u003e\u003cstrong data-start=\"2152\" data-end=\"2164\"\u003eVoltage:\u003c\/strong\u003e 120V AC \/ 60 Hz or 110V AC \/ 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pmhfsn\" data-start=\"2202\" data-end=\"2229\"\u003e\n\u003cp data-start=\"2204\" data-end=\"2229\"\u003e\u003cstrong data-start=\"2204\" data-end=\"2218\"\u003ePipe Size:\u003c\/strong\u003e 3\/8\" NPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bq5u39\" data-start=\"2230\" data-end=\"2257\"\u003e\n\u003cp data-start=\"2232\" data-end=\"2257\"\u003e\u003cstrong data-start=\"2232\" data-end=\"2249\"\u003eOrifice Size:\u003c\/strong\u003e 5\/16\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1acydkd\" data-start=\"2258\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2260\" data-end=\"2290\"\u003e\u003cstrong data-start=\"2260\" data-end=\"2281\"\u003eFlow Coefficient:\u003c\/strong\u003e Cv 1.2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8h1wh9\" data-start=\"2291\" data-end=\"2319\"\u003e\n\u003cp data-start=\"2293\" data-end=\"2319\"\u003e\u003cstrong data-start=\"2293\" data-end=\"2310\"\u003eMax Pressure:\u003c\/strong\u003e 15 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10ih0zu\" data-start=\"2320\" data-end=\"2350\"\u003e\n\u003cp data-start=\"2322\" data-end=\"2350\"\u003e\u003cstrong data-start=\"2322\" data-end=\"2342\"\u003eMax Temperature:\u003c\/strong\u003e 125°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1occmb\" data-start=\"2351\" data-end=\"2382\"\u003e\n\u003cp data-start=\"2353\" data-end=\"2382\"\u003e\u003cstrong data-start=\"2353\" data-end=\"2371\"\u003eBody Material:\u003c\/strong\u003e Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dwxjxi\" data-start=\"2383\" data-end=\"2418\"\u003e\n\u003cp data-start=\"2385\" data-end=\"2418\"\u003e\u003cstrong data-start=\"2385\" data-end=\"2403\"\u003eSeal Material:\u003c\/strong\u003e Buna-N (NBR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2o1vwc\" data-start=\"2419\" data-end=\"2469\"\u003e\n\u003cp data-start=\"2421\" data-end=\"2469\"\u003e\u003cstrong data-start=\"2421\" data-end=\"2431\"\u003eMedia:\u003c\/strong\u003e Natural Gas, LP Gas, Air, Inert Gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qqjz5v\" data-start=\"2470\" data-end=\"2513\"\u003e\n\u003cp data-start=\"2472\" data-end=\"2513\"\u003e\u003cstrong data-start=\"2472\" data-end=\"2489\"\u003eBTU Capacity:\u003c\/strong\u003e approx. 64,400 BTU\/hr\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6z7k0q\" data-start=\"2514\" data-end=\"2544\"\u003e\n\u003cp data-start=\"2516\" data-end=\"2544\"\u003e\u003cstrong data-start=\"2516\" data-end=\"2527\"\u003eWeight:\u003c\/strong\u003e approx. 1.3 lb\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o3jqp1\" data-start=\"2545\" data-end=\"2619\"\u003e\n\u003cp data-start=\"2547\" data-end=\"2619\"\u003e\u003cstrong data-start=\"2547\" data-end=\"2575\"\u003eTypical Shipping Weight:\u003c\/strong\u003e ~2 lb \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"osaite\" data-start=\"2626\" data-end=\"2647\"\u003eCommon Applications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1v6jnil\" data-start=\"2649\" data-end=\"2676\"\u003eHVAC \u0026amp; Heating Equipment\u003c\/h2\u003e\n\u003cul data-start=\"2677\" data-end=\"2850\"\u003e\n\u003cli data-section-id=\"mfz6bq\" data-start=\"2677\" data-end=\"2693\"\u003e\n\u003cp data-start=\"2679\" data-end=\"2693\"\u003eGas furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d5evle\" data-start=\"2694\" data-end=\"2710\"\u003e\n\u003cp data-start=\"2696\" data-end=\"2710\"\u003eUnit heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"319ul9\" data-start=\"2711\" data-end=\"2735\"\u003e\n\u003cp data-start=\"2713\" data-end=\"2735\"\u003eRooftop HVAC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6fzbl6\" data-start=\"2736\" data-end=\"2764\"\u003e\n\u003cp data-start=\"2738\" data-end=\"2764\"\u003eHydronic heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1a7yekx\" data-start=\"2765\" data-end=\"2784\"\u003e\n\u003cp data-start=\"2767\" data-end=\"2784\"\u003eRadiant heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9cfc5x\" data-start=\"2785\" data-end=\"2805\"\u003e\n\u003cp data-start=\"2787\" data-end=\"2805\"\u003eInfrared heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"thnu29\" data-start=\"2806\" data-end=\"2821\"\u003e\n\u003cp data-start=\"2808\" data-end=\"2821\"\u003eGas boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wq1s7u\" data-start=\"2822\" data-end=\"2850\"\u003e\n\u003cp data-start=\"2824\" data-end=\"2850\"\u003eCommercial heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"giibqo\" data-start=\"2852\" data-end=\"2882\"\u003eBurner \u0026amp; Combustion Systems\u003c\/h2\u003e\n\u003cul data-start=\"2883\" data-end=\"3082\"\u003e\n\u003cli data-section-id=\"1mtp06p\" data-start=\"2883\" data-end=\"2912\"\u003e\n\u003cp data-start=\"2885\" data-end=\"2912\"\u003eBurner management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"29l2x\" data-start=\"2913\" data-end=\"2938\"\u003e\n\u003cp data-start=\"2915\" data-end=\"2938\"\u003eGas burner assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hn6gum\" data-start=\"2939\" data-end=\"2958\"\u003e\n\u003cp data-start=\"2941\" data-end=\"2958\"\u003ePilot gas lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jd8g0p\" data-start=\"2959\" data-end=\"2985\"\u003e\n\u003cp data-start=\"2961\" data-end=\"2985\"\u003eMain burner gas trains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tk0ep5\" data-start=\"2986\" data-end=\"3013\"\u003e\n\u003cp data-start=\"2988\" data-end=\"3013\"\u003eFlame safeguard systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mewq7\" data-start=\"3014\" data-end=\"3046\"\u003e\n\u003cp data-start=\"3016\" data-end=\"3046\"\u003eCombustion control manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fsutc2\" data-start=\"3047\" data-end=\"3082\"\u003e\n\u003cp data-start=\"3049\" data-end=\"3082\"\u003eIndustrial burner control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"c8r9bk\" data-start=\"3084\" data-end=\"3115\"\u003eIndustrial Heating Equipment\u003c\/h2\u003e\n\u003cul data-start=\"3116\" data-end=\"3276\"\u003e\n\u003cli data-section-id=\"1oyaaum\" data-start=\"3116\" data-end=\"3136\"\u003e\n\u003cp data-start=\"3118\" data-end=\"3136\"\u003eIndustrial ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"owk0x7\" data-start=\"3137\" data-end=\"3161\"\u003e\n\u003cp data-start=\"3139\" data-end=\"3161\"\u003ePowder coating ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gzubm7\" data-start=\"3162\" data-end=\"3184\"\u003e\n\u003cp data-start=\"3164\" data-end=\"3184\"\u003ePaint curing ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"odox8c\" data-start=\"3185\" data-end=\"3203\"\u003e\n\u003cp data-start=\"3187\" data-end=\"3203\"\u003eConveyor ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"199mak5\" data-start=\"3204\" data-end=\"3219\"\u003e\n\u003cp data-start=\"3206\" data-end=\"3219\"\u003eBatch ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1k7fbtp\" data-start=\"3220\" data-end=\"3246\"\u003e\n\u003cp data-start=\"3222\" data-end=\"3246\"\u003eHeat treating furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iih8wr\" data-start=\"3247\" data-end=\"3256\"\u003e\n\u003cp data-start=\"3249\" data-end=\"3256\"\u003eKilns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ybhkp0\" data-start=\"3257\" data-end=\"3276\"\u003e\n\u003cp data-start=\"3259\" data-end=\"3276\"\u003eIndustrial dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11x7c9c\" data-start=\"3278\" data-end=\"3303\"\u003eFood Service Equipment\u003c\/h2\u003e\n\u003cul data-start=\"3304\" data-end=\"3443\"\u003e\n\u003cli data-section-id=\"1kym5wz\" data-start=\"3304\" data-end=\"3331\"\u003e\n\u003cp data-start=\"3306\" data-end=\"3331\"\u003eCommercial bakery ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p721jl\" data-start=\"3332\" data-end=\"3347\"\u003e\n\u003cp data-start=\"3334\" data-end=\"3347\"\u003ePizza ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rg7it0\" data-start=\"3348\" data-end=\"3374\"\u003e\n\u003cp data-start=\"3350\" data-end=\"3374\"\u003eConveyor cooking ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ckkrhu\" data-start=\"3375\" data-end=\"3395\"\u003e\n\u003cp data-start=\"3377\" data-end=\"3395\"\u003eRotisserie ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hmndre\" data-start=\"3396\" data-end=\"3418\"\u003e\n\u003cp data-start=\"3398\" data-end=\"3418\"\u003eCommercial smokers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bvtwsq\" data-start=\"3419\" data-end=\"3443\"\u003e\n\u003cp data-start=\"3421\" data-end=\"3443\"\u003eFood processing dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"ndspc2\" data-start=\"3445\" data-end=\"3481\"\u003eManufacturing \u0026amp; Process Equipment\u003c\/h2\u003e\n\u003cul data-start=\"3482\" data-end=\"3608\"\u003e\n\u003cli data-section-id=\"d02udq\" data-start=\"3482\" data-end=\"3503\"\u003e\n\u003cp data-start=\"3484\" data-end=\"3503\"\u003eThermal oxidizers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hrpwv3\" data-start=\"3504\" data-end=\"3523\"\u003e\n\u003cp data-start=\"3506\" data-end=\"3523\"\u003eProcess heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"29b52f\" data-start=\"3524\" data-end=\"3544\"\u003e\n\u003cp data-start=\"3526\" data-end=\"3544\"\u003eGas-fired dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1elh6fr\" data-start=\"3545\" data-end=\"3579\"\u003e\n\u003cp data-start=\"3547\" data-end=\"3579\"\u003eIndustrial combustion chambers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o656wu\" data-start=\"3580\" data-end=\"3608\"\u003e\n\u003cp data-start=\"3582\" data-end=\"3608\"\u003eGas distribution manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"17wg4k6\" data-start=\"3610\" data-end=\"3635\"\u003eAgricultural Equipment\u003c\/h2\u003e\n\u003cul data-start=\"3636\" data-end=\"3697\"\u003e\n\u003cli data-section-id=\"3al68\" data-start=\"3636\" data-end=\"3652\"\u003e\n\u003cp data-start=\"3638\" data-end=\"3652\"\u003eGrain dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4ue47z\" data-start=\"3653\" data-end=\"3676\"\u003e\n\u003cp data-start=\"3655\" data-end=\"3676\"\u003eCrop drying systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x6v5kb\" data-start=\"3677\" data-end=\"3697\"\u003e\n\u003cp data-start=\"3679\" data-end=\"3697\"\u003eGreenhouse heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"13f8bta\" data-start=\"3704\" data-end=\"3736\"\u003eTypical Installation Locations\u003c\/h1\u003e\n\u003cp data-start=\"3737\" data-end=\"3773\"\u003eThis valve is commonly installed in:\u003c\/p\u003e\n\u003cul data-start=\"3775\" data-end=\"3906\"\u003e\n\u003cli data-section-id=\"11ngi9a\" data-start=\"3775\" data-end=\"3789\"\u003e\n\u003cp data-start=\"3777\" data-end=\"3789\"\u003eGas trains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yvqsn1\" data-start=\"3790\" data-end=\"3816\"\u003e\n\u003cp data-start=\"3792\" data-end=\"3816\"\u003ePilot gas supply lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tlp45s\" data-start=\"3817\" data-end=\"3850\"\u003e\n\u003cp data-start=\"3819\" data-end=\"3850\"\u003eMain burner gas supply piping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11d1yjs\" data-start=\"3851\" data-end=\"3875\"\u003e\n\u003cp data-start=\"3853\" data-end=\"3875\"\u003eCombustion manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1khjkqy\" data-start=\"3876\" data-end=\"3906\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3906\"\u003eBurner safety shutoff stages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"hg9dub\" data-start=\"3913\" data-end=\"3931\"\u003ePackage Includes\u003c\/h1\u003e\n\u003cul data-start=\"3932\" data-end=\"4025\"\u003e\n\u003cli data-section-id=\"i2xmhz\" data-start=\"3932\" data-end=\"3983\"\u003e\n\u003cp data-start=\"3934\" data-end=\"3983\"\u003e(1) ASCO 8040H008 Gas Combustion Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"f2cmad\" data-start=\"3984\" data-end=\"4025\"\u003e\n\u003cp data-start=\"3986\" data-end=\"4025\"\u003eFactory-installed coil (120\/60, 110\/50)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42642965954656,"sku":"8040H008","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/series8040.jpg?v=1773759768"},{"product_id":"8210g002-120-60-110-50-ac-solenoid-valve","title":"8210G002 120\/60, 110\/50 AC 1\/2\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650477822048,"sku":"8210G002","price":194.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g003-120-60-110-50-ac-3-4-general-service-solenoid-valve","title":"8210G003 120\/60, 110\/50 AC 3\/4\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650478182496,"sku":"8210G003","price":302.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g004-120-60-110-50-ac-1-general-service-solenoid-valve","title":"8210G004 120\/60, 110\/50 AC 1\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650480443488,"sku":"8210G004","price":384.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g008-120-60-110-50-ac-1-1-4-general-service-solenoid-valve","title":"8210G008 120\/60, 110\/50 AC 1-1\/4\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\" title=\"Series 8210 General Service Solenoid Valve Spec Sheet\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650563477600,"sku":"8210G008","price":467.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g009-120-60-110-50-ac-3-4-general-service-solenoid-valve","title":"8210G009 120\/60, 110\/50 AC 3\/4\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650564165728,"sku":"8210G009","price":202.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g015-120-60-110-50-ac-1-2-general-service-solenoid-valve","title":"8210G015 120\/60, 110\/50 AC 1\/2\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650570195040,"sku":"8210G015","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g034-120-60-110-50-ac-1-2-general-service-solenoid-valve","title":"8210G034 120\/60, 110\/50 AC 1\/2\" General Service Solenoid Valve N.O.","description":"\u003cp\u003e2 way, pilot operated, normally open general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650570719328,"sku":"8210G034","price":385.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g035-120-60-110-50-ac-3-4-general-service-solenoid-valve","title":"8210G035 120\/60, 110\/50 AC 3\/4\" General Service Solenoid Valve N.O.","description":"\u003cp\u003e2 way, pilot operated, normally open general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650571145312,"sku":"8210G035","price":401.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g054-120-60-110-50-ac-1-general-service-solenoid-valve","title":"8210G054 120\/60, 110\/50 AC 1\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650571407456,"sku":"8210G054","price":510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g055-120-60-110-50-ac-1-1-4-general-service-solenoid-valve","title":"8210G055 120\/60, 110\/50 AC 1-1\/4\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650572423264,"sku":"8210G055","price":574.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g056-120-60-110-50-ac-1-1-2-general-service-solenoid-valve","title":"8210G056 120\/60, 110\/50 AC 1-1\/2\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650573504608,"sku":"8210G056","price":773.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g075-120-60-110-50-ac-1-2-gas-shutoff-solenoid-valve","title":"8210G075 120\/60, 110\/50 AC 1\/2\" Gas Shutoff Solenoid Valve","description":"\u003cp\u003e2 way, normally closed, pilot operated gas shutoff valve for control of commercial and industrial burners and ideal for high pressure applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_NCR2.pdf?v=1773352680\" title=\"Series 8210 Gas Shutoff Valve Spec Sheet\"\u003eSeries 8210 Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650575634528,"sku":"8210G075","price":316.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g074-120-60-110-50-ac-3-8-gas-shutoff-solenoid-valve","title":"8210G074 120\/60, 110\/50 AC 3\/8\" Gas Shutoff Solenoid Valve","description":"\u003cp\u003e2 way, normally closed, pilot operated gas shutoff valve for control of commercial and industrial burners and ideal for high pressure applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_NCR2.pdf?v=1773352680\" title=\"Series 8210 Gas Shutoff Valve Spec Sheet\"\u003eSeries 8210 Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650591395936,"sku":"8210G074","price":329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g093-120-60-110-50-ac-3-8-general-service-solenoid-valve","title":"8210G093 120\/60, 110\/50 AC 3\/8\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650653130848,"sku":"8210G093","price":223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g094-120-60-110-50-ac-1-2-general-service-solenoid-valve","title":"8210G094 120\/60, 110\/50 AC 1\/2\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650669187168,"sku":"8210G094","price":223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8210g095-120-60-110-50-ac-3-4-general-service-solenoid-valve","title":"8210G095 120\/60, 110\/50 AC 3\/4\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650669482080,"sku":"8210G095","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8214g010-120-60-110-50-ac-3-8-watertight-gas-shutoff-valve","title":"8214G010 120\/60, 110\/50 AC 3\/8\" Watertight Gas Shutoff Valve","description":"\u003cp\u003e2 way, normally closed, watertight gas shutoff valves with zero differential piloted diaphragm for on-off control of fuel gas in commercial and industrial burners.  Valves provided with 1\/8\" NPT upstream and downstream pipe taps for routine testing\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8214_Compact_R1.pdf?v=1773352681\" title=\"Series 214 Gas Shutoff Valve Spec Sheet\"\u003eSeries 214 Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650682654816,"sku":"8214G010","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/ASCO_214_New.jpg?v=1775153817"},{"product_id":"8214g020-120-60-110-50-ac-1-2-watertight-gas-shutoff-valve","title":"8214G020 120\/60, 110\/50 AC 1\/2\" Watertight Gas Shutoff Valve","description":"\u003cp\u003e2 way, normally closed, watertight gas shutoff valves with zero differential piloted diaphragm for on-off control of fuel gas in commercial and industrial burners.  Valves provided with 1\/8\" NPT upstream and downstream pipe taps for routine testing\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8214_Compact_R1.pdf?v=1773352681\" title=\"Series 214 Gas Shutoff Valve Spec Sheet\"\u003eSeries 214 Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650687635552,"sku":"8214G020","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/ASCO_214_New.jpg?v=1775153817"},{"product_id":"8214g030-120-60-110-50-ac-3-4-watertight-gas-shutoff-valve","title":"8214G030 120\/60, 110\/50 AC 3\/4\" Watertight Gas Shutoff Valve","description":"\u003cp\u003e2 way, normally closed, watertight gas shutoff valves with zero differential piloted diaphragm for on-off control of fuel gas in commercial and industrial burners.  Valves provided with 1\/8\" NPT upstream and downstream pipe taps for routine testing\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8214_Compact_R1.pdf?v=1773352681\" title=\"Series 214 Gas Shutoff Valve Spec Sheet\"\u003eSeries 214 Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650691534944,"sku":"8214G030","price":281.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/ASCO_214_New.jpg?v=1775153817"},{"product_id":"8215b070-csa-120-60-110-50-ac","title":"8215B070 CSA 120\/60, 110\/50 AC 1-1\/2\" Gas Solenoid Valve","description":"\u003cp\u003e2 way, lightweight, direct acting or piloted aluminum valves ideal for low pressure air and fuel gas service applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8040_8215R8.pdf?v=1773352686\" title=\"Series 8040 and 8215 Spec Sheet\"\u003eSeries 8040 and 8215 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650709622880,"sku":"8215B070","price":611.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/215_New.jpg?v=1775153817"},{"product_id":"8215b080-csa-120-60-110-50-ac-2-gas-solenoid-valve","title":"8215B080 CSA 120\/60, 110\/50 AC 2\" Gas Solenoid Valve","description":"\u003cp\u003e2 way, lightweight, direct acting or piloted aluminum valves ideal for low pressure air and fuel gas service applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8040_8215R8.pdf?v=1773352686\" title=\"Series 8040 and 8215 Spec Sheet\"\u003eSeries 8040 and 8215 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42650720436320,"sku":"8215B080","price":891.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/215_New.jpg?v=1775153817"},{"product_id":"8210g076-120-60-110-50-ac-3-4-gas-shutoff-solenoid-valve","title":"8210G076 120\/60, 110\/50 AC 3\/4\" Gas Shutoff Solenoid Valve","description":"\u003cp\u003e2 way, normally closed, pilot operated gas shutoff valve for control of commercial and industrial burners and ideal for high pressure applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_NCR2.pdf?v=1773352680\" title=\"Series 8210 Gas Shutoff Valve Spec Sheet\"\u003eSeries 8210 Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42651299840096,"sku":"8210G076","price":369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"k3a432v-standard-voltage","title":"K3A432V 120\/60 3\/8\" Low Pressure Gas Shutoff Valve","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2-way normally closed operation\u003c\/li\u003e\n\u003cli\u003eDie-cats aluminum body\u003c\/li\u003e\n\u003cli\u003eFor positive shutoff on pilot or main gas lines of commercial and industrial gas burners\u003c\/li\u003e\n\u003cli\u003eValves provided with 1\/8\" NPT upstream and downstream pipe taps with plug for routine testing\u003c\/li\u003e\n\u003cli\u003eBroad ambient temperature range: -40F up to 160F\u003c\/li\u003e\n\u003cli\u003eFor use with fuel gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A4_Low_Pressure_Gas_Shuttoff_Valves.pdf?v=1773352685\" title=\"K3A4 Series Low Pressure Gas Shutoff Valve Spec Sheet\"\u003eK3A4 Series Low Pressure Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42651348861024,"sku":"K3A432V","price":203.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A_Valve.avif?v=1773352657"},{"product_id":"k3a442v-standard-voltage","title":"K3A442V 120\/60 VAC 1\/2\" Low Pressure Gas Shutoff Valve","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2-way normally closed operation\u003c\/li\u003e\n\u003cli\u003eDie-cats aluminum body\u003c\/li\u003e\n\u003cli\u003eFor positive shutoff on pilot or main gas lines of commercial and industrial gas burners\u003c\/li\u003e\n\u003cli\u003eValves provided with 1\/8\" NPT upstream and downstream pipe taps with plug for routine testing\u003c\/li\u003e\n\u003cli\u003eBroad ambient temperature range: -40F up to 160F\u003c\/li\u003e\n\u003cli\u003eFor use with fuel gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A4_Low_Pressure_Gas_Shuttoff_Valves.pdf?v=1773352685\" title=\"K3A4 Series Low Pressure Gas Shutoff Valve Spec Sheet\"\u003eK3A4 Series Low Pressure Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42651348893792,"sku":"K3A442V","price":246.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A_Valve.avif?v=1773352657"},{"product_id":"k3a542v-standard-voltage","title":"K3A542V 120\/60 VAC 1\/2\" High Pressure Gas Shutoff Valve","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2-way normally closed operation\u003c\/li\u003e\n\u003cli\u003eDie-cats aluminum body\u003c\/li\u003e\n\u003cli\u003eFor positive shutoff on pilot or main gas lines of commercial and industrial gas burners\u003c\/li\u003e\n\u003cli\u003eValves provided with 1\/8\" NPT upstream and downstream pipe taps with plug for routine testing\u003c\/li\u003e\n\u003cli\u003eBroad ambient temperature range: -40F up to 160F\u003c\/li\u003e\n\u003cli\u003eFor use with fuel gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"K3A5 Series High Pressure Gas Shutoff Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A5_High_Pressure_Gas_Shuttoff_Valves.pdf?v=1773352685\"\u003eK3A5 Series High Pressure Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42651348959328,"sku":"K3A542V","price":247.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A_Valve.avif?v=1773352657"},{"product_id":"s262sh02n3gj7-120-60","title":"S262SH02N3GJ7  120\/60 1-1\/4\" N.O. Gas Vent Valve","description":"\u003cp\u003eFeatures\u003cbr\u003e• 2-way normally open operation\u003cbr\u003e• Die-cast aluminum bodies\u003cbr\u003e• Zero differential piloted diaphragm\u003cbr\u003e• Valves provided with 1\/8\" NPT pipe taps with plug\u003cbr\u003efor routine testing\u003cbr\u003e• Broad ambient temperature range -20˚F up to 170˚F\u003c\/p\u003e\n\u003cp\u003eFluid\u003cbr\u003eFuel Gas\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/series-s262-gas-vent-valve.pdf?v=1773352687\" title=\"Series S262 Spec Sheet\"\u003eSeries S262 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42651349024864,"sku":"S262SH02N3GJ7","price":775.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/S262SH02N3GJ7.jpg?v=1773352657"},{"product_id":"sc8210g002-120-60-110-50","title":"SC8210G002  120\/60, 110\/50 1\/2\" N.C. Brass Solenoid Valve","description":"\u003cp\u003ePilot operated, general service solenoid valve specifically designed for high temperature applications and with DIN connectors(SC prefix)\u003c\/p\u003e\n\u003cp\u003eFeatures\u003cbr\u003e• Wide range of pressure ratings, sizes, and resilient\u003cbr\u003ematerials provide long service life and low\u003cbr\u003einternal leakage\u003cbr\u003e• High Flow Valves for liquid, corrosive, and air\/inert\u003cbr\u003egas service\u003cbr\u003e• Industrial applications include:\u003cbr\u003e- Car wash - Laundry equipment\u003cbr\u003e- Air compressors - Industrial water control\u003cbr\u003e- Pumps\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352687\" title=\"Series 8210 Spec Sheet\"\u003eSeries 8210 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42651349057632,"sku":"SC8210G002","price":200.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075.jpg?v=1773352657"},{"product_id":"8043b037-csa-120-60-110-50","title":"8043B037 CSA  120\/60, 110\/50 AC 3\/4\" Gas Shutoff Valve","description":"\u003cp\u003eFeatures\u003cbr\u003e• Unique double disc design with overtravel provides\u003cbr\u003eredundant sealing for leak tight shutoff\u003cbr\u003e• Visual indication of open and shut position\u003cbr\u003e• Proof of closure switch 1 amp\u003cbr\u003e• 2-way normally closed operation\u003cbr\u003e• Zero differential piloted diaphragm\u003cbr\u003e• For on-off control of fuel gas in commercial and\u003cbr\u003eindustrial gas burners\u003cbr\u003e• Valves provided with 1\/8\" NPT upstream and\u003cbr\u003edownstream pipe taps with plugs for routine testing\u003cbr\u003e• 5 lb. closing spring for high force shut-off\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42652987850848,"sku":"8043B037","price":2507.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/series_8043.jpg?v=1773946974"},{"product_id":"hv298568012-1-low-power-gas-shutoff-valve-24vdc","title":"HV298568012 — 1\" Low Power Peak \u0026 Hold Low Temperature Gas Shutoff Valve, 2-Way Normally Closed, 304 Stainless Steel, 24 VDC","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eThe ASCO HV298568012 is a 1\" 2-way normally closed gas shutoff valve built for high-capacity fuel gas service in commercial and industrial burner systems where power draw is a constraint. The peak and hold design pulls 23.6 peak watts for 0.2–0.5 seconds to open, then holds at 0.85 watts via an external PWM controller running a 19% duty cycle (500–2000 Hz). At 13 Cv and 701,000 Btu\/hr, it delivers full 1\" line capacity on a hold-power budget that conventional continuous-duty solenoids can't match — the difference that makes battery-backed, solar, and remote installations practical.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eThe 304 stainless steel body is paired with a 305 stainless core tube, 430F stainless core and plugnut, Inconel springs, and a PTFE rider ring. The 1\" construction uses low-temperature FKM seals and disc with a low-temperature HNBR diaphragm. Ambient rating is -40°F to 125°F (-40°C to 52°C); fluid temperature range is 14°F to 125°F (-10°C to 52°C). Zero minimum operating pressure differential, 50 psi MOPD, 100 psi safe working pressure.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eMounting: this valve must be installed with the solenoid vertical and upright (Const. Ref. 3).\u003c\/strong\u003e It is not position-tolerant.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e CSA Certified for hazardous locations (File 013976), Automatic Gas Valves Z21.21 and CSA 6.5 C\/I Safety Shutoff (File 112872), and CSA C22.2 No. 139 \"Electrically Operated Valves.\" Complies with ANSI\/ISA-12.27.01.2003 single seal requirements and meets NACE MR-0175 metallurgical requirements. Enclosure Types 3, 3S, 4, 4X, 6, 6P, 7, and 9. Consult factory for Canadian Registration Numbers.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv dir=\"auto\" class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHV298568012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHV298568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePipe Size\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOrifice\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCv\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eGas Capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e701,000 Btu\/hr @ 1\" W.C. drop, 2\" W.C. inlet \/ 8,268,480 Btu\/hr @ 10% MOPD drop, 25% MOPD inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating Pressure Differential\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0–50 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSafe Working Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e100 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFluid Temp Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e14°F to 125°F (-10°C to 52°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eAmbient Temp Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-40°F to 125°F (-40°C to 52°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCoil Class\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePeak \/ Hold Watts\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e23.6 \/ 0.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHold PWM Duty Cycle\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e19% @ 500–2000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBody Material\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeals \/ Disc\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLow Temp. FKM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDiaphragm\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLow Temp. HNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCore Tube\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e305 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCore \/ Plugnut\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e430F Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSprings\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInconel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRider Ring\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSpare Coil Family\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e501696\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLeads\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e72\" standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConstruction Ref.\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3 — solenoid vertical and upright\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEnd Connections\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1\" NPT both ends, 2X 1\" ANPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e External PWM controller required — this valve will not operate correctly on straight DC. Supervisory and leakage current above 0.010 amp will cause improper operation. Fuel gas dewpoint must be at least 18°F (10°C) below the minimum temperature any point in the system will see, to prevent condensed water vapor from freezing in the valve.\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":42982781419616,"sku":"HV298568012","price":2720.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/Screenshot2026-07-21115345.png?v=1784649242"},{"product_id":"8210g003-24vdc-3-4-general-service-solenoid-valve","title":"8210G003 24VDC 3\/4\" General Service Solenoid Valve","description":"\u003cp\u003e2 way, pilot operated, general service solenoid valves in a wide range of pressure ratings, sizes, and resilient materials for use with liquids, corrosives, and air\/inert gas in industrial applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Series 8210 General Service Solenoid Valve Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210_-_general.pdf?v=1773352688\"\u003eSeries 8210 General Service Solenoid Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":43039860785248,"sku":"8210G003 24DC","price":302.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8210g075_f842503e-f719-4062-853d-cd8a3918652f.jpg?v=1773762895"},{"product_id":"8040h006-120-60-110-50-ac-1-8-safety-shutoff-valve","title":"8040H006 120\/60, 110\/50 AC 1\/8\" Safety Shutoff Valve","description":"\u003ch3 data-section-id=\"tdf23g\" data-start=\"102\" data-end=\"200\"\u003eASCO 8040H006 Gas Combustion Solenoid Valve – 120V\/60Hz, 110V\/50Hz – Normally Closed – 1\/8\" NPT\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-end=\"236\" data-start=\"145\" data-section-id=\"12h4b5q\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8040_8215R8.pdf?v=1773352686\" target=\"_blank\"\u003e\u003cspan\u003eProduct Spec Sheet (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp data-start=\"202\" data-end=\"519\"\u003eThe \u003cstrong data-start=\"206\" data-end=\"253\"\u003eASCO 8040H006 Gas Combustion Solenoid Valve\u003c\/strong\u003e is a reliable \u003cstrong data-start=\"268\" data-end=\"345\"\u003esafety shut-off valve designed for fuel gas control in combustion systems\u003c\/strong\u003e. This normally closed, electrically operated valve automatically stops gas flow when power is removed, helping protect burners, appliances, and industrial heating equipment.\u003c\/p\u003e\n\u003cp data-start=\"521\" data-end=\"886\"\u003eEngineered for dependable performance, the 8040H006 is commonly used in \u003cstrong data-start=\"593\" data-end=\"652\"\u003eboilers, furnaces, ovens, and other gas-fired equipment\u003c\/strong\u003e where precise and safe gas flow control is essential. When energized, the valve opens to allow gas flow to the burner system. When de-energized, the valve closes immediately to shut off the gas supply, ensuring safe system operation.\u003c\/p\u003e\n\u003cp data-start=\"888\" data-end=\"1181\"\u003eThe valve operates on \u003cstrong data-start=\"910\" data-end=\"950\"\u003e120V AC at 60 Hz or 110V AC at 50 Hz\u003c\/strong\u003e, making it compatible with a wide range of commercial and industrial combustion systems. Its \u003cstrong data-start=\"1044\" data-end=\"1075\"\u003ecompact 1\/8\" NPT connection\u003c\/strong\u003e and durable aluminum body allow for easy installation in both new equipment and replacement applications.\u003c\/p\u003e\n\u003cp data-start=\"1183\" data-end=\"1371\"\u003eBuilt to meet demanding combustion safety requirements, the \u003cstrong data-start=\"1243\" data-end=\"1371\"\u003eASCO 8040 Series valves are widely used across HVAC, industrial heating, food processing, and commercial cooking industries.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1378\" data-end=\"1393\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1394\" data-end=\"1820\"\u003e\n\u003cli data-section-id=\"eky0l8\" data-start=\"1394\" data-end=\"1450\"\u003e\n\u003cp data-start=\"1396\" data-end=\"1450\"\u003eNormally closed \u003cstrong data-start=\"1412\" data-end=\"1450\"\u003egas safety shut-off solenoid valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1casgc2\" data-start=\"1451\" data-end=\"1502\"\u003e\n\u003cp data-start=\"1453\" data-end=\"1502\"\u003e\u003cstrong data-start=\"1453\" data-end=\"1483\"\u003e120V \/ 60Hz or 110V \/ 50Hz\u003c\/strong\u003e coil compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ur8w7k\" data-start=\"1503\" data-end=\"1533\"\u003e\n\u003cp data-start=\"1505\" data-end=\"1533\"\u003e\u003cstrong data-start=\"1505\" data-end=\"1533\"\u003e1\/4\" NPT pipe connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kk67er\" data-start=\"1534\" data-end=\"1577\"\u003e\n\u003cp data-start=\"1536\" data-end=\"1577\"\u003eDesigned for \u003cstrong data-start=\"1549\" data-end=\"1577\"\u003efuel gas and air service\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"256ksj\" data-start=\"1578\" data-end=\"1623\"\u003e\n\u003cp data-start=\"1580\" data-end=\"1623\"\u003eFast response for combustion safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kmw0hr\" data-start=\"1624\" data-end=\"1687\"\u003e\n\u003cp data-start=\"1626\" data-end=\"1687\"\u003eCompact aluminum body for durability and corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lt2qan\" data-start=\"1688\" data-end=\"1753\"\u003e\n\u003cp data-start=\"1690\" data-end=\"1753\"\u003eSuitable for \u003cstrong data-start=\"1703\" data-end=\"1753\"\u003ecommercial, industrial, and OEM burner systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4eako4\" data-start=\"1754\" data-end=\"1820\"\u003e\n\u003cp data-start=\"1756\" data-end=\"1820\"\u003eTrusted ASCO reliability used in combustion control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1827\" data-end=\"1854\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1855\" data-end=\"2281\"\u003e\n\u003cli data-section-id=\"14m303y\" data-start=\"1855\" data-end=\"1878\"\u003e\n\u003cp data-start=\"1857\" data-end=\"1878\"\u003e\u003cstrong data-start=\"1857\" data-end=\"1867\"\u003eModel:\u003c\/strong\u003e 8040H006\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lpn87r\" data-start=\"1879\" data-end=\"1935\"\u003e\n\u003cp data-start=\"1881\" data-end=\"1935\"\u003e\u003cstrong data-start=\"1881\" data-end=\"1896\"\u003eValve Type:\u003c\/strong\u003e 2-Way Normally Closed Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wgnrof\" data-start=\"1936\" data-end=\"1986\"\u003e\n\u003cp data-start=\"1938\" data-end=\"1986\"\u003e\u003cstrong data-start=\"1938\" data-end=\"1950\"\u003eVoltage:\u003c\/strong\u003e 120V AC (60 Hz) \/ 110V AC (50 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"clu3nd\" data-start=\"1987\" data-end=\"2014\"\u003e\n\u003cp data-start=\"1989\" data-end=\"2014\"\u003e\u003cstrong data-start=\"1989\" data-end=\"2003\"\u003ePipe Size:\u003c\/strong\u003e 1\/8\" NPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1occmb\" data-start=\"2015\" data-end=\"2046\"\u003e\n\u003cp data-start=\"2017\" data-end=\"2046\"\u003e\u003cstrong data-start=\"2017\" data-end=\"2035\"\u003eBody Material:\u003c\/strong\u003e Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q8mpwl\" data-start=\"2047\" data-end=\"2089\"\u003e\n\u003cp data-start=\"2049\" data-end=\"2089\"\u003e\u003cstrong data-start=\"2049\" data-end=\"2075\"\u003eFlow Coefficient (Cv):\u003c\/strong\u003e Approx. 1.0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7mxiyb\" data-start=\"2090\" data-end=\"2146\"\u003e\n\u003cp data-start=\"2092\" data-end=\"2146\"\u003e\u003cstrong data-start=\"2092\" data-end=\"2113\"\u003eMaximum Pressure:\u003c\/strong\u003e Up to 15 PSI (Air\/Gas Service)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2o1vwc\" data-start=\"2147\" data-end=\"2197\"\u003e\n\u003cp data-start=\"2149\" data-end=\"2197\"\u003e\u003cstrong data-start=\"2149\" data-end=\"2159\"\u003eMedia:\u003c\/strong\u003e Natural Gas, LP Gas, Air, Inert Gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xpm0iy\" data-start=\"2198\" data-end=\"2233\"\u003e\n\u003cp data-start=\"2200\" data-end=\"2233\"\u003e\u003cstrong data-start=\"2200\" data-end=\"2213\"\u003eMounting:\u003c\/strong\u003e Inline gas piping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bfh3fa\" data-start=\"2234\" data-end=\"2281\"\u003e\n\u003cp data-start=\"2236\" data-end=\"2281\"\u003e\u003cstrong data-start=\"2236\" data-end=\"2247\"\u003eSeries:\u003c\/strong\u003e ASCO 8040 Combustion Safety Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"vx2wyp\" data-start=\"2288\" data-end=\"2310\"\u003eCommon Applications\u003c\/h2\u003e\n\u003cp data-start=\"2311\" data-end=\"2425\"\u003eThe ASCO 8040H006 valve is designed for \u003cstrong data-start=\"2351\" data-end=\"2413\"\u003egas flow control and safety shut-off in combustion systems\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ibt7am\" data-start=\"2427\" data-end=\"2455\"\u003eHVAC \u0026amp; Heating Equipment\u003c\/h3\u003e\n\u003cul data-start=\"2456\" data-end=\"2685\"\u003e\n\u003cli data-section-id=\"mfz6bq\" data-start=\"2456\" data-end=\"2472\"\u003e\n\u003cp data-start=\"2458\" data-end=\"2472\"\u003eGas furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"weau2w\" data-start=\"2473\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2475\" data-end=\"2495\"\u003eCommercial heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d5evle\" data-start=\"2496\" data-end=\"2512\"\u003e\n\u003cp data-start=\"2498\" data-end=\"2512\"\u003eUnit heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qfg2xq\" data-start=\"2513\" data-end=\"2535\"\u003e\n\u003cp data-start=\"2515\" data-end=\"2535\"\u003eRooftop HVAC units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cba75p\" data-start=\"2536\" data-end=\"2562\"\u003e\n\u003cp data-start=\"2538\" data-end=\"2562\"\u003eGas-fired air handlers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9cfc5x\" data-start=\"2563\" data-end=\"2583\"\u003e\n\u003cp data-start=\"2565\" data-end=\"2583\"\u003eInfrared heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xz8sev\" data-start=\"2584\" data-end=\"2608\"\u003e\n\u003cp data-start=\"2586\" data-end=\"2608\"\u003eRadiant tube heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6fzbl6\" data-start=\"2609\" data-end=\"2637\"\u003e\n\u003cp data-start=\"2611\" data-end=\"2637\"\u003eHydronic heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tbg3kq\" data-start=\"2638\" data-end=\"2660\"\u003e\n\u003cp data-start=\"2640\" data-end=\"2660\"\u003eCondensing boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ec5opk\" data-start=\"2661\" data-end=\"2685\"\u003e\n\u003cp data-start=\"2663\" data-end=\"2685\"\u003eNon-condensing boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"k8smhh\" data-start=\"2687\" data-end=\"2714\"\u003eBoiler \u0026amp; Burner Systems\u003c\/h3\u003e\n\u003cul data-start=\"2715\" data-end=\"2902\"\u003e\n\u003cli data-section-id=\"irbh4z\" data-start=\"2715\" data-end=\"2737\"\u003e\n\u003cp data-start=\"2717\" data-end=\"2737\"\u003eIndustrial boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"llv47s\" data-start=\"2738\" data-end=\"2760\"\u003e\n\u003cp data-start=\"2740\" data-end=\"2760\"\u003eCommercial boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mtp06p\" data-start=\"2761\" data-end=\"2790\"\u003e\n\u003cp data-start=\"2763\" data-end=\"2790\"\u003eBurner management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vw0f5u\" data-start=\"2791\" data-end=\"2818\"\u003e\n\u003cp data-start=\"2793\" data-end=\"2818\"\u003ePilot burner assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jd8g0p\" data-start=\"2819\" data-end=\"2845\"\u003e\n\u003cp data-start=\"2821\" data-end=\"2845\"\u003eMain burner gas trains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tk0ep5\" data-start=\"2846\" data-end=\"2873\"\u003e\n\u003cp data-start=\"2848\" data-end=\"2873\"\u003eFlame safeguard systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11ytbk0\" data-start=\"2874\" data-end=\"2902\"\u003e\n\u003cp data-start=\"2876\" data-end=\"2902\"\u003eCombustion control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1rdqcer\" data-start=\"2904\" data-end=\"2936\"\u003eIndustrial Heating Equipment\u003c\/h3\u003e\n\u003cul data-start=\"2937\" data-end=\"3106\"\u003e\n\u003cli data-section-id=\"1oyaaum\" data-start=\"2937\" data-end=\"2957\"\u003e\n\u003cp data-start=\"2939\" data-end=\"2957\"\u003eIndustrial ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"owk0x7\" data-start=\"2958\" data-end=\"2982\"\u003e\n\u003cp data-start=\"2960\" data-end=\"2982\"\u003ePowder coating ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gzubm7\" data-start=\"2983\" data-end=\"3005\"\u003e\n\u003cp data-start=\"2985\" data-end=\"3005\"\u003ePaint curing ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"199mak5\" data-start=\"3006\" data-end=\"3021\"\u003e\n\u003cp data-start=\"3008\" data-end=\"3021\"\u003eBatch ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"odox8c\" data-start=\"3022\" data-end=\"3040\"\u003e\n\u003cp data-start=\"3024\" data-end=\"3040\"\u003eConveyor ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gg58un\" data-start=\"3041\" data-end=\"3068\"\u003e\n\u003cp data-start=\"3043\" data-end=\"3068\"\u003eHeat treatment furnaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iih8wr\" data-start=\"3069\" data-end=\"3078\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3078\"\u003eKilns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ywnsq\" data-start=\"3079\" data-end=\"3106\"\u003e\n\u003cp data-start=\"3081\" data-end=\"3106\"\u003eDryers and curing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"15v3n0c\" data-start=\"3108\" data-end=\"3152\"\u003eFood Service \u0026amp; Food Processing Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3153\" data-end=\"3301\"\u003e\n\u003cli data-section-id=\"znz54l\" data-start=\"3153\" data-end=\"3173\"\u003e\n\u003cp data-start=\"3155\" data-end=\"3173\"\u003eCommercial ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wujd0v\" data-start=\"3174\" data-end=\"3190\"\u003e\n\u003cp data-start=\"3176\" data-end=\"3190\"\u003eBakery ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ozoh0g\" data-start=\"3191\" data-end=\"3205\"\u003e\n\u003cp data-start=\"3193\" data-end=\"3205\"\u003eDeck ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o6mlz8\" data-start=\"3206\" data-end=\"3230\"\u003e\n\u003cp data-start=\"3208\" data-end=\"3230\"\u003eConveyor pizza ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ckkrhu\" data-start=\"3231\" data-end=\"3251\"\u003e\n\u003cp data-start=\"3233\" data-end=\"3251\"\u003eRotisserie ovens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15nk6nc\" data-start=\"3252\" data-end=\"3264\"\u003e\n\u003cp data-start=\"3254\" data-end=\"3264\"\u003eProofers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"62vt29\" data-start=\"3265\" data-end=\"3280\"\u003e\n\u003cp data-start=\"3267\" data-end=\"3280\"\u003eFood dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18fnppm\" data-start=\"3281\" data-end=\"3301\"\u003e\n\u003cp data-start=\"3283\" data-end=\"3301\"\u003eCommercial smokers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"k24tdt\" data-start=\"3303\" data-end=\"3343\"\u003eManufacturing \u0026amp; Processing Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3344\" data-end=\"3498\"\u003e\n\u003cli data-section-id=\"29b52f\" data-start=\"3344\" data-end=\"3364\"\u003e\n\u003cp data-start=\"3346\" data-end=\"3364\"\u003eGas-fired dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hrpwv3\" data-start=\"3365\" data-end=\"3384\"\u003e\n\u003cp data-start=\"3367\" data-end=\"3384\"\u003eProcess heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d02udq\" data-start=\"3385\" data-end=\"3406\"\u003e\n\u003cp data-start=\"3387\" data-end=\"3406\"\u003eThermal oxidizers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1thidtz\" data-start=\"3407\" data-end=\"3423\"\u003e\n\u003cp data-start=\"3409\" data-end=\"3423\"\u003eIncinerators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13sv1ts\" data-start=\"3424\" data-end=\"3446\"\u003e\n\u003cp data-start=\"3426\" data-end=\"3446\"\u003eIndustrial burners\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ajg1x3\" data-start=\"3447\" data-end=\"3469\"\u003e\n\u003cp data-start=\"3449\" data-end=\"3469\"\u003eGas mixing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o656wu\" data-start=\"3470\" data-end=\"3498\"\u003e\n\u003cp data-start=\"3472\" data-end=\"3498\"\u003eGas distribution manifolds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1u7qc7r\" data-start=\"3500\" data-end=\"3537\"\u003eAgriculture \u0026amp; Specialty Equipment\u003c\/h3\u003e\n\u003cul data-start=\"3538\" data-end=\"3635\"\u003e\n\u003cli data-section-id=\"3al68\" data-start=\"3538\" data-end=\"3554\"\u003e\n\u003cp data-start=\"3540\" data-end=\"3554\"\u003eGrain dryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oz7gmj\" data-start=\"3555\" data-end=\"3577\"\u003e\n\u003cp data-start=\"3557\" data-end=\"3577\"\u003eGreenhouse heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4ue47z\" data-start=\"3578\" data-end=\"3601\"\u003e\n\u003cp data-start=\"3580\" data-end=\"3601\"\u003eCrop drying systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1238n90\" data-start=\"3602\" data-end=\"3635\"\u003e\n\u003cp data-start=\"3604\" data-end=\"3635\"\u003eAgricultural combustion heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1v2qwi5\" data-start=\"3642\" data-end=\"3675\"\u003eTypical Installation Locations\u003c\/h2\u003e\n\u003cp data-start=\"3676\" data-end=\"3712\"\u003eThis valve is commonly installed in:\u003c\/p\u003e\n\u003cul data-start=\"3714\" data-end=\"3869\"\u003e\n\u003cli data-section-id=\"1luek8e\" data-start=\"3714\" data-end=\"3730\"\u003e\n\u003cp data-start=\"3716\" data-end=\"3730\"\u003e\u003cstrong data-start=\"3716\" data-end=\"3730\"\u003eGas trains\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mvcfgu\" data-start=\"3731\" data-end=\"3752\"\u003e\n\u003cp data-start=\"3733\" data-end=\"3752\"\u003e\u003cstrong data-start=\"3733\" data-end=\"3752\"\u003ePilot gas lines\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hrf6mc\" data-start=\"3753\" data-end=\"3787\"\u003e\n\u003cp data-start=\"3755\" data-end=\"3787\"\u003e\u003cstrong data-start=\"3755\" data-end=\"3787\"\u003eMain burner gas supply lines\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"marsxb\" data-start=\"3788\" data-end=\"3822\"\u003e\n\u003cp data-start=\"3790\" data-end=\"3822\"\u003e\u003cstrong data-start=\"3790\" data-end=\"3822\"\u003eCombustion control manifolds\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1563mc6\" data-start=\"3823\" data-end=\"3869\"\u003e\n\u003cp data-start=\"3825\" data-end=\"3869\"\u003e\u003cstrong data-start=\"3825\" data-end=\"3869\"\u003eSafety shut-off stages in burner systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"6hv2og\" data-start=\"3876\" data-end=\"3895\"\u003ePackage Includes\u003c\/h2\u003e\n\u003cul data-start=\"3896\" data-end=\"3976\"\u003e\n\u003cli data-section-id=\"nvc9fh\" data-start=\"3896\" data-end=\"3943\"\u003e\n\u003cp data-start=\"3898\" data-end=\"3943\"\u003e(1) ASCO 8040H006 Combustion Solenoid Valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1e3ymgv\" data-start=\"3944\" data-end=\"3976\"\u003e\n\u003cp data-start=\"3946\" data-end=\"3976\"\u003eFactory-installed 120V AC coil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":67618681520224,"sku":null,"price":133.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/series_8040.jpg?v=1773352657"},{"product_id":"k3a782v-120-60-1-1-2-medium-pressure-gas-shutoff-valve","title":"K3A782V 120\/60 1-1\/2\" Medium Pressure Gas Shutoff Valve","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2-way normally closed operation\u003c\/li\u003e\n\u003cli\u003eDie-cats aluminum body\u003c\/li\u003e\n\u003cli\u003eFor positive shutoff on pilot or main gas lines of commercial and industrial gas burners\u003c\/li\u003e\n\u003cli\u003eValves provided with 1\/8\" NPT upstream and downstream pipe taps with plug for routine testing\u003c\/li\u003e\n\u003cli\u003eBroad ambient temperature range: -40F up to 160F\u003c\/li\u003e\n\u003cli\u003eFor use with fuel gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A7_Medium_Pressure_Gas_Shuttoff_Valves_-_Direct_Acting.pdf?v=1791225215\" title=\"K3A7 Series Medium Pressure Gas Shutoff Valve Spec Sheet\"\u003eK3A7 Series Low Pressure Gas Shutoff Valve Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":67618773139552,"sku":null,"price":487.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/K3A_Valve.avif?v=1773352657"},{"product_id":"8215g080-24-dc-2-gas-solenoid-valve","title":"8215G080 24\/DC 2\" Gas Solenoid Valve","description":"\u003cp\u003e2 way, lightweight, direct acting or piloted aluminum valves ideal for low pressure air and fuel gas service applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/8040_8215R8.pdf?v=1773352686\" title=\"Series 8040 and 8215 Spec Sheet\"\u003eSeries 8040 and 8215 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"ASCO","offers":[{"title":"Default Title","offer_id":67618913452128,"sku":null,"price":1104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/9085\/9616\/files\/215_New.jpg?v=1775153817"}],"url":"https:\/\/ecdistco.com\/collections\/gas-combustion-valves.oembed?page=6","provider":"EC Distribution Co.","version":"1.0","type":"link"}